Slimelite BBS

Problems with Sportster V.34 and TrapDoor 1.85

Back to IBM

From Peter Deane · 1996-03-20 08:34 · #77328 in IBM

In reply to Re: Problems with Sportster V.34 and TrapDoor 1.85 by Mats-Olov Rustad

 PD> The timeout in TrapDoor is about 90 seconds.  What's your S7 setting?
 PD> My bet is greater than 90 seconds????

 MR> I use the Dialtimeout keyword and have set it to 40 while the S7 
 MR> register is set to 60 (one more than the default value 59). I 
 MR> have tried to set the S7 register to a value less than the 
 MR> DialTimeout keyword value and the result was exactly the same, 
 MR> if the called modem doesn't answer TD reports No reaction from 
 MR> modem and termintes prematurely.

S7 should really be less than the timeout, so the MODEM will give up on the call before TRAPDOOR, thus giving TrapDoor a chance to grab any text (eg NO CARRIER) returned by the modem.

 MR> You mean that the Sportster V.34 is more of a problem since it 
 MR> has a faster CPU and thus responds more quickly to AT commands?

I'm in no way sure.  But it's probably a timing problem in that an Arexx command to make a call is being fired off a little too quickly before TrapDoor is completely finished with the one before.

TrapDoor stops looking for incoming characters when the Aftersession is underway, I'm betting that's what's causing the problems.  IE your dial Command is coming too quickly, TrapDoor's not looking for the characters just at that point, and so gives you a No Response from Modem as a result.   Fingers crossed.

  Mea Culpa,
 Peter Deane

--- Plutonic 2.13 #1
 * Origin: Inquestor. Hydra for TrapDoor, THANX! +61-43-961587 (3:711/476)