From Denis McMahon · 1996-04-10 01:38 · #75429 in DARKSIDE_CODE

In reply to Hazard flashing by Ben Lovejoy

Hi Ben

 It appears that on Sat 06 Apr 
 Ben Lovejoy said to Denis McMahon ....

 DM>> Given the wide range of permitted flash
 DM>> frequencies for indicators, it is unlikely that an on-off pattern will
 DM>> ever be distinguishable between indicator and hazard

BL> No reason why not. The permitted range of frequencies is /very/ broad.

Indicator flash has to be between 60 and 120 a minute. A blown bulb generally causes a quicker flash (less heating effect of current so faster recovery time), but even this is usually still in the permitted range.

On vehicles where the same can is used for hazard and indicator, the can usually operates at a constant rate over the current range that the two different systems use (generally 4 to 8 amps or thereabouts), and cans are generally designed for 90 fpm in the specified current range with the 60-120 flash rate variation used to absorb manufacturing tolerances.

The current technology does not easily lend itself to different and distinguishable flash rates for indication and hazard. It's possible that the hazard flash could be made much slower than indicator flash, but then you'd be at risk of loosing the "faster than normal flash" indication that a bulb had failed, and you'd still quite likely be within the "permitted" range for indicators.

Rgds
Denis