central office) to the customer premises. Its maximum length may be
5.5 km (18000 ft). The equipment on both sides of the U loop has to be
carefully designed to deal with the long length of the U loop and the
noisy environment it operates in.
At the customer premises the U-loop is terminated by an NT1 (network
termination 1) device. The NT1 drives an S/T-bus which is usually 4
wires, but in some cases it may be 6 or 8 wires. In these optional
cases, the extra wires are used provide power to operate telephones
when normal power fails. Alternately, 'phantom' power may be derived
from the standard four wires. Outside of North America emergency mode
operation provides power for basic voice service only in the case of
loss of local power. In emergency mode operation the NT1 receives up
to 1.2W from the central office. In North America there is no provision
for emergency mode operation.
The name of the S/T bus comes from the letters used in the ISDN
specifications used to refer to two reference points, S and T. Point T
refers to the connection between the NT1 device and customer supplied
equipment. Terminals can connect directly to NT1 at point T, or there
may be a PBX (private branch exchange, i.e. a customer-owned telephone
exchange). When a PBX is present, point S refers to the connection
between the PBX and the terminal. Note that in ISDN terminology,
"terminal" can mean any sort of end-user ISDN device, such as data
terminals, telephones, FAX machines, etc.
This picture shows what a residential ISDN connection looks like.
Point T Point U |
+--------+ 4-8 wires +-------+ 2-4 wires |
|Terminal|-----+-----| NT1 |-------------[| wall (to telco CO)
+--------+ | +-------+ |
+--------+ | |
|Terminal|-----+
+--------+ |
:
+--------+ |
|Terminal|-----+
+--------+
The T bus is a multipoint bus in this configuration. It is sometimes
called the passive bus because there are no repeaters on the line
between the NT1 and the devices. It can be implemented using the same
cable and connectors as is 10 base T Ethernet. There may be up to 8
devices on the S/T bus. The bus may be formed with splitters and T
connectors - it is a bus, not a star. The D channel is used to control
the attachment of the one to eight devices to the two B channels. No
two devices attach to the same B channel at the same time.
In this configuration, the major function of the NT is to allow more
than one device to have access to the 2 B channels provided by the ISDN
BRI. For instance, you may have an ISDN telephone, an ISDN fax and an
ISDN computer interface attached to the BRI. Each device can listen
for calls and only connect to a B channel when it identifies a message
requesting a service it can provide.
The NT1 only implements part of the channel sharing scheme; the other
devices participate as well, and the communication protocol used by the
NT1 and the other devices is an integral part of the scheme. The NT1
also performs other functions; it translates the bit encoding scheme
used on the lines between it and the telephone company (the U loop) to
the encoding used between it and the devices. These schemes are
different because the device to NT encoding was designed to enable
channel sharing whereas the NT to telco encoding was designed to allow
transmission across long distances.
In the United States, the customer pays for the NT device, so don't
forget to include the cost of this unit in your cost estimates, or if
you don't need the multiple device attachment feature, try to find a
device that does not require the NT device (i.e. it attaches directly
to the U loop). If you are not in the United States the telephone
company provides the NT device, but remember there is no such thing as
a free lunch - you are probably paying for it through increased rates,
or increased taxes, etc. (flames to sci.economics or alt.talk.politics).
Unfortunately, the NT1 is not an inexpensive device. It has to convert
between the signalling used on the U loop (which is operates over long
distances (5.5 km, 18000 ft) in a noisy environment and does not have
to deal with contention between devices) and the signalling of the S/T
bus (which operates over shorter distances in a quieter environment but
it does have to deal with contention between devices and other protocol
functions). It also provides diagnostic functions such as loopback
mode, and it may have to provide power, as descibed above.
This picture shows what an ISDN connection looks like when a PBX is
present.
Point S Point T Point U |
+--------+ 4-8 wires +-------+ 4-8 wires +-------+ 2-4 wires |
|Terminal|-----------| NT2 |-----------| NT1 |-----------[| wall
+--------+ | (PBX) | +-------+ |
Point S +---+---+ |
+--------+ _________/ |
|Terminal|/ | Point S
+--------+ |
+---+----+
|Terminal|
+--------+
In this configuration, the wires at points S and T are point-to-point
links. Electrically, the S and T points are the same, which is why the
name S/T bus is almost always used. This makes sense; the terminal
should see the same physical interface whether it is hooked up with or
without a PBX. But, logically they are different. The telephone
company needs to know that there is a PBX between itself and the user
so that it can coordinate its efforts with the PBX. So, in cases where
the difference is important, the specifications use the S and T
terminology.
When there is no PBX in the configuration, the NT1 device is usually a
standalone device that is packaged a lot like a modem: in a small box
when there are only a few, and in a rackmount when you need a lot of
them. In the United States, the customer buys the NT1 but in most of
the rest of the world the telephone company provides the NT1. When
there is a PBX the rackmounted NT1s are quite common. Also, when
there is a PBX the use of PRI lines instead of BRI lines is common.
cherkus@unimaster.com (Dave Cherkus)
cliff@Berkeley.EDU (Cliff Frost)
curt@kcwc.com (Curt Welch)
dror@digibd.com (Dror Kessler)
Eric_Boll-RXNN70Q@email.sps.mot.com (Eric Boll)
glarson@bnr.ca (Greg Larson)
krowett@large.cisco.com (Kevin J. Rowett)
mea@intgp1.att.com (Mark Anderson)
paul@suite.sw.oz.au (Paul Antoine)
pturner@eng.auburn.edu ( Patton M. Turner)
ronnie@cisco.com (Ronnie B. Kon)
------------------------------
2.04) What is a NT1? Who sells them?
[ Ed Note: Some may feel that there's a bit of overlap between the
preceding sections and this one, but the preceding sections are
hard to write without integrating NT1 information and this one
is so informative and well-written that it can stand on its own
so I think I should leave it as is. Comments? ]
Reply: What's an NT1, why do I need one, and where do I get one?
An NT1 (network terminator 1) is a device which provides an interface
between the two-wire twisted pairs used by telephone companies in
their ISDN Basic Rate (BRI) network and an end-user's four-wire
terminal equipment. The NT1 also provides power for the terminal
equipment if necessary (most ISDN phones need power from the NT1, but
most data terminal adapters--TAs--don't).
Most ISDN central office equipment (including AT&T 5ESS and Northern