From Dave Barron · 1996-04-01 23:46 · #69110 in KERRANG
Hiya Jonathan, If you can't find anything resembling a battery, you're probably right in your guess, but check the timer / LED assembly for its own nicad / lithium / silver oxide battery. If you can't find one, check that the big cap's being fed with 5 volts(ish) from the pcb. Then remove it and recheck the pcb voltage if it was low before. See whether the cap holds charge (Don't exceed 5.5v and observe polarity!). If it doesn't remain at near its charge voltage for hours, then it's likely to be dodgy. The only other thing that might be a problem, is that a 3.3 farad cap may be intended to keep the main 5v line smoothed and to overcome power cuts of up to a few seconds. This wouldn't affect the timer. If you do decide to replace it, RS used to do a 5 farad cap at 5v (working) which would do the trick. I'd give you the part number, but I've lost /mislaid the cat. HTH BTW, in response to your other question about coiling your aerial cable: If the SWR is low, you shouldn't be radiating too much from the cable itself. If you start running QRO (high power), then think about better cable and keeping it uncoiled. At 4 watts o/p, you've got nothing to worry about, but keep disks and tapes away from the cable anyway. Running (say) an electic fire with the flex coiled _is_ asking for trouble as the induced field around the coils can induce enough heat to melt the cable. Before I forget; once you're happy with your SWR, take the meter out of the line and only re-insert it if your Tx power reading looks wrong. The meter and its connectors will create many refections of their own (read up on time-domain reflectometry / transmission line theory for an explanation) and certainly won't improve Tx or Rx performance. Cheers, ___ __ __ _ __ | \/ \ | | _| | o | o | | | _| |___/__|_|\ /___| --- * TLX v4.10 * Cheer up. Nothing's so bad, it can't get worse! --- WILDMAIL!/WC v4.12 * Origin: Ooh! LONDON [LiveChat-MultiLines] 0181-395-3108 (2:254/233.0)